Training Board SINAMICS G120

Item No.: 40720

Already known from the Siemens SCE program, the SINAMICS G120 frequency inverter is now also available as a learning board.

Whether you are doing exercises for pumping, ventilating, compressing, moving or processing: SINAMICS G120 is the universal drive for the most diverse requirements.

All connections are led out to the front panel with 4mm safety lab jacks. A motor can be connected either via the laboratory sockets or the parallel available connection socket. The extensive protective functions protect the drive and the connected motor.

Power supply 1-phase 230 V AC, output 3-phase 230 V for motors with up to 0.75 kW rated power.

Siemens provides the "starter" commissioning software free of charge for commissioning and parameterization. It can be downloaded from the Siemens website, as well as the manuals for the inverter.

The learning board is equipped with a SINAMICS Power Module PM240-2:

  • Power factor 0.85
  • Displacement angle cos phi 0,95
  • Efficiency 0,96
  • Power supply 1-phase 200-240 V AC, 47-63 Hz
  • Output 3-phase 230 V AC
  • Output frequency 0 - 200 Hz with vector control
  • Output frequency 0 - 550 Hz with V/f control
  • Rated output current 4.2 A at low overload operation
  • Max. Output current 6.4 A briefly at high overload operation
  • Rated power 0.75 kW for low overload operation
  • Rated power 0.55 kW for high overload operation
     

A SINAMICS Control Unit CU250S-2 PN:

  • Communication via PROFINET/ Ethernet/IP
  • 15 digital inputs (4 configurable as outputs)
  • 2 changeover relay outputs
  • 2 analog inputs
  • 2 analog outputs
  • Motor temperature sensor connection
  • Motor encoder connections
     

Selectable regulatory procedures:

  • V/f linear/ square/ parameterizable
  • V/f with flux current control
  • V/f ECO linear/ square
  • Vector control, sensorless or with encoder
  • Torque control, sensorless or with encoder
     

Protective functions:

  • For the inverter: Over- and undervoltage protection, phase failure, overcurrent, overload, overtemperature
  • For the motor: temperature monitoring, overspeed, blocking and tilting protection
  • Torque monitoring for the drive
  • Monitoring of telegram failure and bus interruption for communication
  • Fault message memory for 8 faults with 8 fault values each, buffer for 56 warnings
     

And an intelligent operator panel:

  • Plain text display (parameters, faults and warnings in plain text, help texts)
  • Display of status values in bar charts
  • Menu navigation
  • Application Wizard
  • Switching between automatic and manual operation
  • Direct manual operation of the drive possible
  • Learning Board with Power Module PM240-2
  • Control Unit CU250S-2 PN
  • Intelligent Operator Panel