Training Board Fire Alarm Board

Item No.: 54455

With the Fire Alarm training board, all systems of an alarm system can be examined step by step, up to the complete system. The individual components can be freely connected. This allows a step-by-step entry up to the complete commissioning of the entire system. A fire alarm control panel and a key depot are integrated, as are the following signalling devices:

  • Acoustic alarm
  • Flashing light
  • Alarm transmission by main detector

Note: The matching experiment instructions must be ordered separately.

Our products are designed for the European market and meet CE requirements. For international use, regional regulations apply which must be observed. The usability of the products shown must therefore be checked in advance.

Built-in component:

  • 2 thermal differential detectors (infrared)
  • Smoke detector
  • Manual call point
  • Main detector with connection to the fire department control center
  • Key depot
  • Inner and outer horn
  • Optical displays in case of alarm (LEDs)
  • 4 terminating resistors
  • Fire alarm control panel:
  • Key switch, for blocking the forwarding of fire alarms to the main detector
  • Inputs: LIN 1 / LINE 2 / status door / status key / feedback
  • Outputs: ALARM OUT / relay K1 / 12 V EXTERNAL / door opener
  • Indicators (LEDs): Operation ON, Operation OFF / ALARM / ERROR / ERROR OFF, ALARM for LINE 1 and LINE 2 / key depot unlocked / status of key depot
  • Button: Horn off / RESET / OFF, ON for LINE 1 and LINE 2
  • Simulation: power failure and missing battery

To carry out experiments, the training board is placed on the table or hung in an A4 experiment rack for demonstration. The training board is also available in a box (see "Matching this").

  • Electronics technician for energy and building technology
  • Electronics technician
  • Electronics technician for industrial engineering
  • Electronics technician for building and infrastructure systems

With the training board set Fire Alarm System, we offer a teaching and learning system that is ideally suited for the following experimental groups:

  • General information
  • VdS guidelines
  • Components of a fire alarm system
  • Optical smoke detectors
  • Detector zones of the FIRE ALARM BOARD
  • The fire alarm center of the FIRE ALARM BOARD
  • Mains connection:
  • Mains voltage: 230 V AC / 115 V AC (110 V AC)
  • Mains frequency: 50 ... 60 Hz
  • Power consumption: approx. 10 VA
  • Dimensions (W x H x D): 532 x 297 x 120 mm
  • Weights: approx. 3,0 kg
  • Thermal differential detector (infrared):
  • Operating voltage: 12 V DC
  • Optical smoke detector:
  • Operating voltage: 12 V
  • Manual call point:
  • The glass panel is simulated by a plexiglass sliding door.
  • The alarm is indicated by a red LED.
  • The alarm is triggered by a push button.
  • Operating voltage: 12 V
  • Main detector:
  • The alarm is indicated by a red LED.
  • Main detector in idle mode, green LED lights up
  • The alarm is triggered by a push button.
  • Additional indication by a red LED in case of an alarm message to the fire department control center
  • Operating voltage: 12 V
  • Alarm center:
  • Voltage output: 12 V DC / 0.2 A

All inputs and outputs are connected via 2 mm sockets.

Mechanical specifications:

The front panel of the training board is made of 5 mm thick laminate, color matt blue, and is engraved with white switching symbols corresponding to the built-in function groups. A sturdy plastic cover protects the rear of the unit and its shape allows the unit to be placed at an ergonomically favourable angle on the table.

  • Training board Fire Alarm