Training Board VPS Overload Relay

Item No.: 98144

  • Learning board Electronic overload relay with auxiliary switch
  • A4 learning board for use in an A4 experimental frame, e.g. on a Laboratory bench
  • Setting range from 1.90 to 6.30 A
  • Manual/automatic reset
  • Tripping class 10E, 20E, 30E
  • Phase loss sensitive
  • Learning board electronic overload relay with auxiliary switch
  • 19 mm jumper plug (without centre tap): 1x red, 1x blue

Training companies and schools in trade and industry in the electrical engineering sector

Learning Field 8, in the following professions:

  • Electronics technician for automation technology: selecting and integrating drive systems
  • Electronics engineer for industrial engineering: Selecting and integrating drive systems
  • Electronics technicians for energy and building services engineering: Selecting and integrating drive systems
  • Electronics technician for building and infrastructure systems: Extending building services systems according to business management aspects
  • Electronics technicians for devices and systems and system electronics technicians: Manufacturing and testing devices
  • Electronics engineer for machine and drive technology: Integrating electrical machines and mechanical components
  • Dimensions (L x W x H): 105 x 297 x 96 mm
  • Weight: 0,74 Kg
  • Setting range: 1.90 ... 6.30 A
  • Rated operational voltage (Ue):  
    • Main circuit 690 V AC
    • Auxiliary circuit 600 V AC/DC
  • Rated operational current (Ie): 6.30 A
  • Rated operational current AC-3 (Ie): 6.30 A
  • Rated frequency (fr):   
    • Main circuit 50 Hz
    • Main circuit 60 Hz
    • Auxiliary circuit DC
    • Auxiliary circuit 50 Hz
    • Auxiliary circuit 60 Hz
  • Rated impulse withstand voltage (Uimp):
    • Main circuit 6 kV
    • Auxiliary circuit 6 kV
  • Rated insulation voltage (Ui): 690 V
  • Number of poles: 3
  • Number of auxiliary contacts break contact: 1
  • Number of auxiliary contacts make contact: 1
  • Number of protected poles: 3
  • Conventional continuous thermal current in free air (Ith):  
    • Auxiliary circuit Ö 6 A
    • Auxiliary circuit S 6 A
  • Rated operational current AC-15 (Ie): 
    • (240V) Ö 3 A
    • (400V) Ö 1.1 A
    • (500V) S 0.75 A
    • (240V) S 3 A
    • (400V) S 1.1 A
    • (500V) Ö 0.75 A
  • Rated operational current DC-13 (Ie): 
    • (24V) Ö 1.5 A
    • (60V) Ö 0.55 A
    • (125V) Ö 0.55 A
    • (250V) Ö 0.27 A
    • (24V) S 1.5 A

Variants