Training Board Auxiliary Contactor
Hard-Wired PLC

Item No.: 98155

Learning board contactor with auxiliary contacts

A4 learning board for use in an A4 experimental frame, e.g. on a laboratory bench.

  • 400 V 7.4 A
  • 2 auxiliary contacts (1NC, 1NO)
  • Control voltage 24 to 60 V


The contactor is self-disturbing and has overvoltage protection.

  • Learning board contactor with auxiliary contacts
  • 19 mm jumper plug (without centre tap): 1x red, 1x blue

Training companies and schools in trade and industry in the electrical engineering sector

Learning Field 8, in the following professions:

  • Electronics technician for automation technology: selecting and integrating drive systems
  • Electronics engineer for industrial engineering: Selecting and integrating drive systems
  • Electronics technicians for energy and building services engineering: Selecting and integrating drive systems
  • Electronics technician for building and infrastructure systems: Extending building services systems according to business management aspects
  • Electronics technicians for devices and systems and system electronics technicians: Manufacturing and testing devices
  • Electronics engineer for machine and drive technology: Integrating electrical machines and mechanical components
  • Dimensions (L x W x H): 157.5 x 297 x 96 mm
  • Weight: 1,12 Kg
Main contactor data:
  • Rated operational power AC-3 (Pe): 
    • (220 / 230 / 240V) 4 kW
    • (380 / 400V) 7.5 kW
    • (415V) 9 kW
    • (440V) 9 kW
    • (500V) 9 kW
    • (690V) 9 kW
  • Rated operational current AC-1 (Ie): 
    • (690V) 40°C 30 A
    • (690V) 60°C 30 A
    • (690V) 70°C 26 A
  • Number of main contacts N/O contact: 3
  • Number of auxiliary contacts make contact: 1
  • Rated control voltage (Uc): 
    • 50 Hz 24...60 V
    • 60 Hz 24...60 V
    • DC operation 20...60 V
Data Auxiliary contacts (2 pieces):
  • Rated operational current AC (Ie):  
    • (220 / 240 V) 4 A
    • (24 / 127 V) 6 A
    • (400 / 440 V) 3 A
    • (500 V) 2 A
    • (690 V) 2 A
  • Rated operational current DC (Ie):  
    • (110 V) 0.55 A / 60 W
    • (220 V) 0.27 A / 60 W
    • (400 V) 0.15 A / 60 W
    • (500 V) 0.13 A / 65 W
    • (600 V) 0.1 A / 60 W
    • (125 V) 0.55 A / 69 W
    • (24 V) 6 A / 144 W
    • (250 V) 0.27 A / 68 W
    • (48 V) 2.8 A / 134 W
    • (72 V) 1 A / 72 W
  • Rated operating voltage: Auxiliary circuit 24 ... 690 V
  • Number of auxiliary contacts break contact: 1
  • Number of auxiliary contacts make contact: 1

Variants


Matching this


Documents